H125/H151/H200M/H200/H300 Multi-Media Filter Systems
WATER QUALITY
BACK
DIMENSIONS 1
EST.
CF
WASH
SHIP
MODEL PIPE FILTER TANK SUPERIOR HIGH UTILITY FLOW TOTAL INLET OUTLET DRAIN WIDTH WT.
SIZE MEDIA SIZE
RATE
H 2
I
O
D
W
LBS.
H125-MM10-1
1.25
1
10X44
4
7
9
8
51
46
46
57
11
190
H125-MM10-1.5
1.25
1.5
10X54
4
7
9
8
63
57
57
58
11
224
H125-MM13-2
1.25
2
13X54
7
11
14
14
63
57
57
58
14
312
H125-MM14-3
1.25
3
14X65
9
13
16
16
74
68
68
69
15
443
H125-MM16-4
1.25
4
16X65
11
17
21
20
74
67
70
68
17
624
H125-MM18-5
1.25
6
18X65
14
21
26
25
76
68
71
69
19
720
H151-MM14-3
1.5
3
14X65
9
13
16
16
74
68
69
70
15
453
H151-MM16-4
1.5
4
16X65
11
17
21
20
74
68
69
70
17
584
H151-MM18-5
1.5
6
18X65
14
21
26
25
76
69
70
71
19
730
H151-MM21-6
1.5
7
21X62
19
29
36
35
72
65
67
67
22
856
H200M-MM14-3
2
3
14X65
9
13
16
16
78
69
69
78
15
468
H200-M-MM16-4
2
4
16X65
11
17
21
20
78
69
69
78
17
649
H200M-MM-18-5
2
5
18X65
14
21
26
25
80
71
71
80
19
745
H200M-MM-21-6
2
6
21X62
19
29
36
35
80
71
71
80
22
886
H200M-MM-24-8
2
8
24X72
25
38
47
45
88
79
79
88
25
1405
H200-MM-24-8 3
2
10
24X72
25
38
47
45
89
83
87
85
25
1410
H200-MM30-15 3
2
15
30X72
39
59
74
75
86
80
84
82
31
2040
H200-MM-36-20 3
2
20
36X72
56
85
106
105
87
81
85
83
37
2620
H300-MM-36-20 3
3
20
36X72
56
85
106
105
104
96
96
100
37
2720
H300-MM-42-30 3
3
30
42X72
77
115
144
145
109
102
102
104
43
3580
1 All dimensions are ± 1”
2 Allow additional 12” for media loading
3 Available in top-mount or side-mount
Service and backwash flow rates are based on 50ºF incoming
water temperature.
Operating parameters - pressure range 40-100 PSI; temperature
range 40º-110ºF.
Product improvement designs are subject to change without notice
As a general rule - Lower flows produce higher quality water and a
larger volume of treated water between backwashing.
Superior
Recommended for most filtering applications under all operating
conditions. 8 gpm/ft 2
Best quality water
Maximum time on line between backwashing
Lowest pressure loss
H125
H151
H200M
Recommended for influent suspended solids loads up to and
greater than 300 ppm.
Consult ’s engineering department for additional sizes, modifi -
cations or special applications.
High
Well suited for many filtering applications. 12 gpm/ft 2
Very good quality water
Moderate time on line between backwashing
Increased pressure loss
Recommended for influent suspended solids loads less than 300
ppm.
Utility
Flow rates listed are at peak design - operation at higher flow rates
not recommended. 15 gpm/ft 2
Satisfactory water quality
Shorter on line time
Higher pressure loss
Recommended for influent suspended solids loads less than 150
ppm.
Media: Anthracite, Filter Sand, Garnet and Support Bed.
1-800-626-1417
www..com
800311
2/12 - LBRY
©2009-2012