H125/H151/H200M/H200/H300 Filter-Ag Systems
WATER QUALITY
BACK
DIMENSIONS 1
EST.
CF
WASH
SHIP
MODEL PIPE FILTER TANK SUPERIOR HIGH UTILITY FLOW TOTAL INLET OUTLET DRAIN WIDTH WT.
SIZE MEDIA SIZE
RATE
H 2
I
O
D
W
LBS.
H125-FA-10-1
1.25
1
10x44
3
4
5
5
51
46
46
50
11
100
H125-FA-10-1.5
1.25
1.5
10x54
3
4
5
5
63
57
57
58
11
110
H125-FA-13-2
1.25
2
13x54
5
7
9
9
63
57
57
58
14
160
H125-FA-14-3
1.25
3
14x65
5
8
11
10
74
68
68
69
15
220
H125-FA-16-4
1.25
4
16x65
7
10
14
15
74
67
70
68
17
325
H125-FA-18-5
1.25
5
18x65
9
13
18
18
76
68
71
69
19
345
H125-FA-21-6
1.25
6
21x62
12
18
24
25
72
65
67
67
22
380
H151-FA-14-3
1.5
3
14x65
5
8
11
10
74
68
69
70
15
225
H151-FA-16-4
1.5
4
16x65
7
10
14
15
74
68
69
70
17
285
H151-FA-18-5
1.5
5
18x65
9
13
18
18
76
69
70
71
19
355
H151-FA-21-6
1.5
6
21x62
12
18
24
25
72
65
67
67
22
405
H151-FA-24-8
1.5
8
24x72
16
24
31
30
82
75
76
77
25
630
H200M-FA-14-3
2
3
14x65
5
8
11
10
78
69
69
78
15
240
H200M-FA-16-4
2
4
16x65
7
10
14
15
78
69
69
78
17
350
H200M-FA-18-5
2
5
18x65
9
13
18
18
80
71
71
80
19
370
H200M-FA-21-6
2
6
21x62
12
18
24
25
80
71
71
80
22
435
H200M-FA-24-8
2
8
24x72
16
24
31
30
88
79
79
88
25
655
H200M-FA-30-15
2
15
30x72
25
37
49
50
89
80
80
89
31
915
H200-FA-24-8 3
2
8
24x72
16
24
31
30
89
83
87
85
25
710
H200-FA-30-15 3
2
15
30x72
25
37
49
50
86
80
84
82
31
915
H200-FA-36-20 3
2
20
36x72
35
53
71
70
87
81
85
83
37
1120
H200-FA-42-30 3
2
30
42x72
48
72
96
95
105
98
102
101
43
1400
H300-FA-36-20 3
3
20
36x72
63
94
126
70
104
96
96
100
37
1220
H300-FA-42-30 3
3
30
42x72
48
72
96
95
109
102
102
108
43
1330
H300-FA-48-40 3
3
40
48x72
63
94
126
125
109
102
102
108
43
1740
H300-FA-54-45 3
3
45
54x60
80
119
159
160
93
85
85
89
51
2700
1 All dimensions are ± 1”
2 Allow additional 12” for media loading
3 Available in top-mount or side-mount
  • Service and backwash flow rates are based on 50ºF incoming
  • water temperature.
  • Operating parameters - pressure range 40-100 PSI; temperature
  • range 40º-110ºF.
  • Product improvement designs are subject to change without notice
  • As a general rule - Lower flows produce higher quality water and a
    larger volume of treated water between backwashing.
    Superior
  • Recommended for most filtering applications under all operating
  • conditions.
  • Best quality water
  • Maximum time on line between backwashing
  • Lowest pressure loss
  • Recommended for influent suspended solids loads up to and
  • greater than 300 ppm.
    H125
    H200M
    High
    H151
  • Well suited for many filtering applications
  • Consult ’s engineering department for additional sizes, modifi -
  • Very good quality water
  • Moderate time on line between backwashing
  • cations or special applications.
  • Increased pressure loss
  • Recommended for influent suspended solids loads less than 300
  • ppm.
    Utility
  • Flow rates listed are at peak design - operation at higher flow rates
  • not recommended
  • Satisfactory water quality
  • Shorter on line time
  • Higher pressure loss
  • Recommended for influent suspended solids loads less than 150
  • ppm.
    1-800-626-1417
    www..com
    800310
    2/12 - LBRY