HRO 3-2000 Reverse Osmosis System
Standard Features:
  • Membrane: Three 2.5” x 40” TFC Extra Low Energy
  • Low Pressure Switch: One Low Pressure Switch –
  • Membranes – For maximum rejection of
    Safety device which protects the pump from running
    impurities and high flow. (PN: 107613)
    dry when there is insufficient feed water pressure.
  • Membrane Housing: Three 2.5” x 40” Membrane
  • Feed Solenoid Valve: One Solenoid Valve with Manual
  • Housings – Feature a patented design and require no
    Override 110 or 220 Volt 50 or 60 Hertz UL Approved
    tools when servicing.
    – Assists with the on/off functionality of the system.
  • Pump: One 5.3 GPM NSF Approved Brass Rotary
  • Product Flow Meter: 0-2 GPM Flow Meter – For
  • Vane Pump – Directly couples to the motor and is de-
    monitoring the system’s product flow.
    signed for continuous high pressures.
  • Concentrate Flow Meter: 0-5 GPM Flow Meter – For
  • Motor: One 3/4 HP Motor 110 or 220 Volt 50 or 60
  • monitoring the system’s concentrate flow.
    Hertz CSA and RU (UL recognized).
  • Concentrate Valve: One 1/4” Stainless Steel Needle
  • Frame: One Aluminum White Powder Coated Frame –
  • Valve – Regulates the system’s recovery (product to
    Corrosion resistant and light weight.
    waste ratio).
  • Sediment Filter: One 4.5” x 20” 5 Micron
  • Concentrate Recirculation: One 1/4” Stainless Steel
  • Polypropylene Filter – Removes sediments and protects
    Needle Valve with 0-2 GPM Flow Meter – For optimum
    the system. (PN: 107569)
    system recovery and performance.
  • Carbon Block: One 4.5” x 20” 10 Micron
  • Product Water Quality Meter: Panel Mount TDS Meter
  • Carbon Block – Removes Chlorine, odors, and taste.
    (G SERIES ONLY) For monitoring the system’s product
    (PN:107440)
    water quality
  • Filter Housing: Two 4.5” x 20” Double
  • Switch: One Manual On and Off Switch
  • O-Ring Filter Housings – Offers durability and
  • Easy Maintenance & Operation: HRO 3 reverse osmo-
  • improved sealing capabilities.
    sis systems feature a compact design, are pre-plumbed,
  • Pressure Gauges: One 2.5” 0-300 PSI Panel Mount
  • pre-wired, and have all their components strategically
    Glycerin Filled Gauge and Two 1.5” 0-160 PSI Bottom
    located for easy access and inspection.
    Mount Dry Gauges – For
    monitoring the system’s operating pressure and the
    filter & carbon operating pressure.
    System Specifications:
    Systems Operating Specifications:
    Model
    HRO 3-2000 S Series
    Part#
    107038
    Minimum Feed Pressure
    35 psi
    Minimum NaCl % Rejection
    96%
    HRO 3-2000 G Series
    Part#
    107039
    Minimum Feed (GPM)
    3.5
    Maximum Hardness
    <1 gpg
    Gallons Per Day
    2000 @ 77ºF*
    Dimensions (Approx)
    19”x23”x46”
    Maximum TDS
    2000 ppm
    Operating Pressure
    150 psi
    1625 @ 55ºF*
    Weight (Approx)
    115 lbs.
    Nominal NaCl%
    Rejection 98.5%
    Maximum Feed (GPM)
    10
    Elements (Qty)
    3
    Motor HP
    3/4
    pH Range
    3-11
    Maximum Temperature
    105ºF
    Element Size (in)
    HF4-2540
    Hertz
    50 or 60
    Operation Atmospheric Tank or Direct Feed
    Feed Connection
    1”
    Voltage
    110 or 220
    Note: Optional level controls or
    Product Connection
    3/8”
    Recovery
    50*
    pressure switch required
    Waste Connection
    3/8”
    * Gallons per day and recovery are dependent upon the feed water chemistry. Specifically,
    but not limited to, temperature and total dissolved solids (TDS). A complete raw water
    analysis may be required to determine actual performance.
    404 Moravian Valley Road • Waunakee, WI 53597
    www..com • info@.com
    2/6/13-LBRY