HRO 3-2000 Reverse Osmosis System
Standard Features:
Membrane: Three 2.5” x 40” TFC Extra Low Energy
Low Pressure Switch: One Low Pressure Switch –
Membranes – For maximum rejection of
Safety device which protects the pump from running
impurities and high flow. (PN: 107613)
dry when there is insufficient feed water pressure.
Membrane Housing: Three 2.5” x 40” Membrane
Feed Solenoid Valve: One Solenoid Valve with Manual
Housings – Feature a patented design and require no
Override 110 or 220 Volt 50 or 60 Hertz UL Approved
tools when servicing.
– Assists with the on/off functionality of the system.
Pump: One 5.3 GPM NSF Approved Brass Rotary
Product Flow Meter: 0-2 GPM Flow Meter – For
Vane Pump – Directly couples to the motor and is de-
monitoring the system’s product flow.
signed for continuous high pressures.
Concentrate Flow Meter: 0-5 GPM Flow Meter – For
Motor: One 3/4 HP Motor 110 or 220 Volt 50 or 60
monitoring the system’s concentrate flow.
Hertz CSA and RU (UL recognized).
Concentrate Valve: One 1/4” Stainless Steel Needle
Frame: One Aluminum White Powder Coated Frame –
Valve – Regulates the system’s recovery (product to
Corrosion resistant and light weight.
waste ratio).
Sediment Filter: One 4.5” x 20” 5 Micron
Concentrate Recirculation: One 1/4” Stainless Steel
Polypropylene Filter – Removes sediments and protects
Needle Valve with 0-2 GPM Flow Meter – For optimum
the system. (PN: 107569)
system recovery and performance.
Carbon Block: One 4.5” x 20” 10 Micron
Product Water Quality Meter: Panel Mount TDS Meter
Carbon Block – Removes Chlorine, odors, and taste.
(G SERIES ONLY) For monitoring the system’s product
(PN:107440)
water quality
Filter Housing: Two 4.5” x 20” Double
Switch: One Manual On and Off Switch
O-Ring Filter Housings – Offers durability and
Easy Maintenance & Operation: HRO 3 reverse osmo-
improved sealing capabilities.
sis systems feature a compact design, are pre-plumbed,
Pressure Gauges: One 2.5” 0-300 PSI Panel Mount
pre-wired, and have all their components strategically
Glycerin Filled Gauge and Two 1.5” 0-160 PSI Bottom
located for easy access and inspection.
Mount Dry Gauges – For
monitoring the system’s operating pressure and the
filter & carbon operating pressure.
System Specifications:
Systems Operating Specifications:
Model
HRO 3-2000 S Series
Part#
107038
Minimum Feed Pressure
35 psi
Minimum NaCl % Rejection
96%
HRO 3-2000 G Series
Part#
107039
Minimum Feed (GPM)
3.5
Maximum Hardness
<1 gpg
Gallons Per Day
2000 @ 77ºF*
Dimensions (Approx)
19”x23”x46”
Maximum TDS
2000 ppm
Operating Pressure
150 psi
1625 @ 55ºF*
Weight (Approx)
115 lbs.
Nominal NaCl%
Rejection 98.5%
Maximum Feed (GPM)
10
Elements (Qty)
3
Motor HP
3/4
pH Range
3-11
Maximum Temperature
105ºF
Element Size (in)
HF4-2540
Hertz
50 or 60
Operation Atmospheric Tank or Direct Feed
Feed Connection
1”
Voltage
110 or 220
Note: Optional level controls or
Product Connection
3/8”
Recovery
50*
pressure switch required
Waste Connection
3/8”
* Gallons per day and recovery are dependent upon the feed water chemistry. Specifically,
but not limited to, temperature and total dissolved solids (TDS). A complete raw water
analysis may be required to determine actual performance.
404 Moravian Valley Road • Waunakee, WI 53597
www..com • info@.com
2/6/13-LBRY
©2012